Clinical and Economic Considerations for Funders
The night is as important as the day
For health authorities, program authorizers, long-term care operators, insurers, and the clinicians who write the request.
Funding often covers the wheelchair and stops there. Without the right support surface and positioning at night, the progress made during the day can be lost.
Progress can be lost at night
Without lying intervention, secondary complications can continue to progress despite appropriate seating and standing programs.
The day depends on the night
Positioning during the day “can be influenced by the position adopted overnight,” and providing postural supports in only one orientation “can be counter-productive.”
The guideline asks for all 24 hours
“Consider an individual’s positioning needs over a 24-hour period when developing a repositioning regimen. This should include where and when they sleep, lie and sit.”
The right surface at night
Alternating pressure air surfaces “are usually reserved for individuals at higher risk or deteriorating skin condition or clinical condition.”2 of 39 vs 13 of 37Nursing-home residents with a new pressure injury within 30 days: alternating pressure vs viscoelastic foam (randomized trial)
“Change does not happen overnight, it happens at night.”
1 · The 24-hour plan
The bed is the other half of the day
RESNA’s 2025 position paper describes lying posture care as the foundational element of 24-hour posture care and recommends it as standard practice: “Best practice for care of individuals with impaired movement should address positioning in all three human orientations, including lying, sitting and standing.” [1]
Up to 12 hours a day
In the same posture when lying unsupported · people with limited mobility
People with mobility impairments often have difficulty changing position or holding a stable midline position when lying on their backs. Lying unsupported, they “may spend up to 12 hours per day in the same destructive postures, which equates to 4,368 hours per year.”
Up to 4,368 hours a year: up to 12 hours a day, every day for 52 weeks.
RESNA, 2025 [1]
Long-term care sees this often. In two multicentre studies in Germany of 2,012 people aged 65 and over, 19.3% of nursing-home residents had at least one contracture, compared with 7.7% of hospital patients. Across both settings, people who were bedridden had about four times the odds of a contracture. [7]
When a request covers the wheelchair, ask what supports the same person in bed: positioning supports for lying on the back and on the side, and the right support surface.
Read more: Getting Started with 24-Hour Positioning · When Seating Isn’t Enough
2 · The support surface
When the surface should be reassessed
The 2026 International Guideline makes re-evaluating the support surface good practice after any immobility-related pressure injury (SS12), because the surface an injury developed on “usually does not provide an appropriate environment for healing.” [4] Consider changing the surface when, for example, an injury fails to heal despite comprehensive management and optimal topical wound care, cannot be offloaded, or the current surface is uncomfortable or bottoms out. [4]
Guideline recommendations
Heat or moisture at the skin
The guideline suggests low air loss where heat and moisture contribute (SS11).
Stage 2–4 or unstageable injury
The guideline suggests low air loss for Stage 2–4 and unstageable injuries (SS15).
Selection follows the person’s full assessment (SS4). [4]
When to consider a powered surface
Seven signs to consider a powered surface in long-term care
Any one of these signs is a reason to assess whether a powered surface could better meet the resident’s needs.
Thinking of a resident? Tap the signs they show.
Also consider changing the surface when a resident with an existing pressure injury is uncomfortable or bottoming out on it (Guideline SS12).
PRESSURE 2 signs are the trial authors’ advice. The guideline suggests low air loss for Stage 2–4 or unstageable injuries (SS15), and that it could be used for people at risk, “especially when moisture and heat at the skin-surface interface are contributing factors” (SS11).
Sauvage et al., 2017 · Nixon et al., PRESSURE 2, 2019 · International Guideline (EPUAP/NPIAP/PPPIA), 2026 · BC PISWC mattress algorithm, 2026 · PRESSURE 2 ↗ · Sauvage 2017 ↗ · Guideline ↗ · BC algorithm ↗
General guide · By type of surface
Support surface options by risk level and pressure injury stage
Powered surfaceAlternating pressure and true low air loss: Stage 1 – Stage 4
Powered surfaceAlternating pressure and micro low air loss: High Risk – Stage 3
Foam with non-powered air-filled inserts: Low Risk – Stage 1
Foam mattressGel-infused memory foam: Low Risk – High Risk
Foam mattressMedical grade: Low Risk – Medium Risk
- Powered surface
- Non-powered
Where ranges overlap, the seven signs help decide when to consider a powered surface. See the seven signs · Request a Trial
Lateral rotation and turn assist aren’t plotted: they’re chosen for repositioning and handling needs, not by stage.
3 · Equipment and care
Equipment works with care, not instead of it
Positioning supports and the right mattress work together. Repositioning continues on every surface, because “no support surface can entirely replace repositioning,” and the interval is individualized to the surface and the person’s response. [3]
The guideline addresses turn-assist surfaces directly: where adequate turn angle and offloading can be achieved, turn assist “might reduce the occupational health and safety risk with repositioning,” and automated turning may suit people who need frequent repositioning or have limited access to help. [3]
Skin care, continence care and nutrition continue alongside the surface.
4 · Total cost of care
Compare the full cost of care, not the price
CA$44K–$90K
Net hospital cost · per hospital-acquired Stage 2–4 pressure injury · Ontario
Injuries already present on admission still cost CA$11,000–18,500 each.
Cost rises with the stage: Stage 2 $44K; Stage 4 $90K.
Chan et al., 2013 · Ontario hospital data [9]
Ontario cost-effectiveness analysis · long-term care
“The clinical and economic evidence supports pressure redistribution mattresses for all long-term care residents.”
Compared with foam, Cochrane estimates 39 fewer new pressure injuries per 1,000 people on alternating pressure and judges it “probably more cost-effective” for prevention. [11]
As Wounds Canada puts it, “cost effectiveness, rather than straight cost, should be considered in conjunction with patient satisfaction and care provider satisfaction.” [12]
Posture has costs too. Without lying intervention, secondary complications can continue to progress despite appropriate seating and standing programs. These complications can eventually require more invasive responses, including orthopaedic surgery, tone-reducing medication or botulinum toxin. [1]
The cost of an injury often lands in a different budget from the one that bought the equipment. Compare the full cost of care, using your local costs.
Read more: Making the Case for Powered Support Surfaces in Long-Term Care
5 · Funding programs
Funding programs to ask about
Coverage depends on each program’s criteria and the clinician’s request. These programs are worth asking about. Each name opens its entry in our funding directory, with the program’s own sources.
Workers’ compensation
Auto insurance
Federal programs
Provincial programs
Health authorities and care homes
Charities and foundations
Workplace and private plans
6 · For the clinician writing the request
What a strong funding request includes
- Risk score, and the tool used
- Skin and tissue response
- Pressure injuries: stage, location and number, and which surfaces the person can be turned onto without pressure on an injury
- Ability to reposition, and the help needed
- Heat or moisture at the skin
- Posture and sleeping position; hours in bed and in the chair
- The current surface: type, age and condition, including bottoming out
- Comfort, pain and sleep
- Goals of care
- The 24-hour plan: bed, chair and positioning supports
- Trial dates, and what changed during the trial
- Review date
A sample rationale to adapt
Fill in the brackets. Leave out names and other identifying details.
Assessed on [date] by [discipline]. Risk: [tool and score]. Skin and tissue: [findings]. Pressure injuries: [stage, location and number; surfaces the person can be turned onto without pressure on an injury]. Mobility: [ability to reposition; help needed]. Microclimate: [heat or moisture at the skin]. Posture: [sleeping position; hours in bed and in the chair]. Current surface: [type, age, condition; bottoming out]. Comfort: [pain; sleep].
The 2026 International Guideline makes surface selection part of a full assessment (SS4), and makes re-evaluating the surface good practice after a pressure injury (SS12). It suggests low air loss where heat and moisture contribute (SS11) and for Stage 2–4 and unstageable injuries (SS15), and asks teams to plan positioning across the full 24 hours, including the hours in bed.
Request: [support surface type], with positioning supports for lying on the back and on the side. Trial: [dates], and what changed. Goals of care: [goals]. Review: [date].
Sources: the International Guideline’s support surfaces and repositioning chapters. [4][3]
From Evergreen
- Letters of Justification: OpalAir · OpalAir Turn · Palm
- Powered-surface request worksheet (PDF)
- Support Surface Selection Guide
- For community clients: funding programs by province and the benefits-check worksheet
These links describe Evergreen’s range. They are not study endorsements or product-specific evidence.
7 · Questions we hear
Answers from the evidence
Isn’t foam enough?
For people at risk, foam is where the guideline starts: it recommends a pressure-redistribution foam surface as the first choice, and says alternating pressure (active) air surfaces “are usually reserved for individuals at higher risk or deteriorating skin condition or clinical condition.” [4] After a pressure injury, re-evaluating the surface is good practice (SS12). [4] In long-term care, the seven signs help decide when to step up.
Does a powered surface mean less repositioning?
No. Repositioning continues on every surface, because “no support surface can entirely replace repositioning.” The interval is individualized to the surface and the person’s response. [3]
Is low air loss only for moisture?
No. The guideline suggests low air loss where heat and moisture contribute (SS11) and for Stage 2–4 and unstageable injuries (SS15). [4]
Does the stage decide the surface?
Not on its own. Selection follows the person’s full assessment (SS4): overall risk of pressure injuries, skin and tissue response, mobility and independence, posture and sleeping position, the need for microclimate management and shear reduction, and preferences and care goals. [4]
Is turn assist the same as repositioning?
No. Where adequate turn angle and offloading can be achieved, turn assist “might reduce the occupational health and safety risk with repositioning.” [3] It helps staff reposition, and it is chosen for repositioning and handling needs, not by stage.
Is 24-hour positioning only for children?
No. RESNA’s 2025 position paper recommends lying posture care as standard practice. [1] In two multicentre studies of 2,012 people aged 65 and over, 19.3% of nursing-home residents had at least one contracture, and people who were bedridden had about four times the odds of a contracture. [7]
Is the price the cost?
Not on its own. As Wounds Canada puts it, “cost effectiveness, rather than straight cost, should be considered in conjunction with patient satisfaction and care provider satisfaction.” [12] In Ontario hospitals, a hospital-acquired Stage 2–4 pressure injury cost CA$44,000 to CA$90,000. [9]
Talk to Evergreen
Plan a trial with your team
Request a trial of a powered surface or positioning cushions, or an in-service for your team. Evergreen replies within 1–3 business days.
An Evergreen educational summary of published studies and guidelines. Practical examples illustrate application. The sources do not endorse Evergreen or its products. Support surfaces do not replace repositioning. Selection and use should be based on individual clinical assessment and the product instructions for use.
References
- 1. Toole PJ, Kittelson T, Hoffman LA, Hutson J, Bopes K. RESNA position on assistive technology for lying posture care management. Rehabilitation Engineering and Assistive Technology Society of North America; approved February 26, 2025. Published in: Assistive Technology. 38(1):51–60. doi:10.1080/10400435.2025.2543691.
- 2. Osborne LJ, Gowran RJ, Casey J. Evidence for 24-hour posture management: a scoping review. Br J Occup Ther. 2023;86(3):176–187. doi:10.1177/03080226221148414. pp. 177, 183, 185.
- 3. European Pressure Ulcer Advisory Panel, National Pressure Injury Advisory Panel, Pan Pacific Pressure Injury Alliance. Repositioning and Mobilization. In: Prevention and Treatment of Pressure Ulcers/Injuries: International Clinical Practice Guideline. 4th ed.; chapter version dated 14 May 2026, published online 24 August 2026. internationalguideline.com/repositioning.
- 4. National Pressure Injury Advisory Panel, European Pressure Ulcer Advisory Panel, Pan Pacific Pressure Injury Alliance. Full Body Support Surfaces (version date 19 October 2026: SS3; SS4, p. 6; SS11, p. 13; SS12 with its supporting text and implementation considerations, p. 14; alternating pressure for people with pressure injuries, p. 15; SS15, p. 16). In: Haesler E, ed. Prevention and Treatment of Pressure Ulcers/Injuries: Clinical Practice Guideline. The International Guideline. 4th ed. 2026. https://www.internationalguideline.com/surfaces
- 5. Sauvage P, Touflet M, Pradere C, et al. Pressure ulcers prevention efficacy of an alternating pressure air mattress in elderly patients: E²MAO a randomised study. J Wound Care. 2017;26(6):304–312. doi:10.12968/jowc.2017.26.6.304. Turning frequency, Table 3 (p. 309); authors’ conclusion, p. 312.
- 6. Hoffman LA. 24-hour posture care management: Change does not happen overnight, it happens at night. Directions (NRRTS). 2017;(5):24–31.
- 7. Neef HE, Müller-Werdan U, Strube-Lahmann S, Lahmann NA. Contractures: prevalence and associated factors in hospitals and nursing homes — results from two consecutive multicenter cross-sectional studies. Nurs Res Pract. 2026;2026:8458386. doi:10.1155/nrp/8458386.
- 8. Nixon J, Brown S, Smith IL, et al. Comparing alternating pressure mattresses and high-specification foam mattresses to prevent pressure ulcers in high-risk patients: the PRESSURE 2 RCT. Health Technol Assess. 2019;23(52). Implications for practice, p. 99. doi:10.3310/hta23520
- 9. Chan B, Ieraci L, Mitsakakis N, Pham B, Krahn M. Net costs of hospital-acquired and pre-admission pressure ulcers among older people hospitalised in Ontario. J Wound Care. 2013;22(7):341–346. doi:10.12968/jowc.2013.22.7.341. https://doi.org/10.12968/jowc.2013.22.7.341
- 10. Pham B, Stern A, Chen W, et al. Preventing pressure ulcers in long-term care: a cost-effectiveness analysis. Arch Intern Med. 2011;171(20):1839–1847. doi:10.1001/archinternmed.2011.473
- 11. Shi C, Dumville JC, Cullum N, Rhodes S, McInnes E, Goh EL, Norman G. Beds, overlays and mattresses for preventing and treating pressure ulcers: an overview of Cochrane Reviews and network meta-analysis. Cochrane Database Syst Rev. 2021;(8):CD013761. doi:10.1002/14651858.CD013761.pub2. Abstract p. 2; Table 2, pp. 35–36. https://pmc.ncbi.nlm.nih.gov/articles/PMC8407250/
- 12. Norton L, Parslow N, Ho C, O’Sullivan-Drombolis D, Rogers A, Parsons A, Moss L. Best practice recommendations for the prevention and management of pressure injuries. In: Best Practice Recommendations for Skin Health and Wound Management 2025. Toronto: Wounds Canada; 2025. Chapter 7, pp. 3, 19, 22, 36. doi:10.56885/GRYI5585. https://www.woundscanada.ca/health-care-professional/publications/bpr-new